Sign In | Join Free | My himfr.com
Home > Induced Draft Fan >

CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan

Xinxiang SIMO Blower Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan from wholesalers
     
    Buy cheap CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan from wholesalers
    • Buy cheap CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan from wholesalers
    • Buy cheap CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan from wholesalers
    • Buy cheap CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan from wholesalers

    CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan

    Ask Lasest Price
    Brand Name : SIMO
    Model Number : SIMO Blower 8-12
    Certification : CE, ISO9001:2008,TUV
    Price : 300-5000 USD
    Payment Terms : T/T, L/C, Payment Term Is Negotiable
    Supply Ability : 500 Sets Per Month
    Delivery Time : 15-35 Days
    • Product Details
    • Company Profile

    CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan

    Industrial CFB Boiler Explosion Protection Induced Draft Blower Fan


    Introduction


    The Industrial CFB Boiler Explosion Protection Induced Draft Blower Fan is designed to work in the high efficiency area to achieve energy saving when operating under variable operating conditions.

    It is jointly designed by the fan energy-saving group of the Ministry of Machinery Industry and organized by the national fan industry.

    It’s a high-performance product promoted by the State Economic Commission and the Ministry of Machinery Industry.

    Industrial CFB Boiler Explosion Protection Induced Draft Blower Fan has the advantages of high efficiency, low noise, wide performance and high efficiency curve.

    Applicable to industrial boilers of 5 ~ 35 tons/hour, the similar intake conditions and performance can be adapted, but the maximum temperature should not exceed 250 °C.

    The dust removal device with a dust removal efficiency of not less than 85% must be installed before the induced draft fan, in order to reduce the dust content of the flue gas entering the fan, which not only reduces the pollution of the flue gas to the environment, but also reduces the wear of the dust on the fan. It’s conducive to extending the life of the fan.


    Technical data

    seriesmodel

    Blower Fan

    Rotation Speed
    (r/min)

    Blower Fan

    Total Pressure
    (Pa)

    Blower Fan

    Air Capacity
    (m³/h)

    Power
    (kW)

    8-12

    Blower Fan

    4D290019422108324268695.57.5
    4.5D290024622805461697817.511
    5D2900303033756333134171522
    5.6D2900380542278897188473037
    6.3D1450120613736334134195.57.5
    7.1D1450153017469066192081115
    8D145019422216129692505918.530
    9D14502462280518466391223745
    10D14503030346225330536665575
    11.2D960145016674345235617539745132
    12.5D7309601206230524907693962275
    14D73096015102972349939749637132
    16D730960197138845223414553375250


    Advantages and Features


    1. It is capable of outputting higher gas pressures and providing more gas flow with lower noise.

    2. In the case of common base, the installation is very simple and requires little support from a professional technician.

    3. The motor shaft is elastically connected with the drive shaft, and it is not necessary to constantly tighten the belt or replace the belt, and the maintenance workload is small.

    4. Fans with an impeller diameter of less than 1400 mm operate at a normal temperature fan system, eliminating the need for additional bearing cooling devices, reducing the amount of user investment and maintenance.

    5. When the airflow resistance is increased, the motor load will be automatically reduced and the motor will not be burnt.

    6. It is made of high quality carbon steel, stainless steel or other metal materials are available upon request.

    7. After the production is completed, after running test and vibration value detection, the operation is reliable.


    FAQ


    1. What parameters need to be provided when you design the industrial centrifugal fans?

    Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

    If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

    2. How about your company’s pre-sales service and after-sales service?

    Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

    After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

    3. Does your company have qualifications?

    Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


    Quality CFB Induced Draft Fan Explosion Protection Id Boiler Draft Fan for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xinxiang SIMO Blower Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)